Updated docs for the Heltec ESP32 Board (#1301)
This commit is contained in:
1 parent
7837369993
commit
fd8c3a79ae
2 files changed
+91
-80
No files matched your search
@@ -27,6 +27,7 @@ The boards below doesn't need hardware modification (or a lite one).
|
||||
|OLIMEX ESP32 Ethernet POE|-|-|-|X|-|X|-|X|
|
||||
|OLIMEX ESP32 Ethernet POE ISO|-|-|-|X|-|X|-|X|
|
||||
|ESP32-WT32-ETH01 Ethernet|-|-|-|X|-|X|-|X|
|
||||
|Heltec WiFi LoRa 32 (V2.1)|-|rtl_433|-|X|X|-|X|-|
|
||||
|[M5Stack Basic](M5)||-|-|X|-|X|X|X|
|
||||
|[M5Tough](M5)|-|-|-|X|-|X|X|X|
|
||||
|M5Stick|-|-|send|X|-|X|-|X|
|
||||
|
||||
+90
-80
@@ -245,7 +245,14 @@ for on:
|
||||
|
||||
## rtl_433 device decoders
|
||||
|
||||
This feature is only available on a ESP32 based device with a CC1101 transceiver connected due to the resource requirements of the rtl_433 device decoders. At the present time only Pulse Position Modulation (OOK_PPM) and Pulse Width Modulation (OOK_PWM) based decoders are available.
|
||||
This feature is only available on a ESP32 based device with a supported transceiver connected due to the resource requirements of the rtl_433 device decoders. At the present time only Pulse Position Modulation (OOK_PPM) and Pulse Width Modulation (OOK_PWM) based decoders are available.
|
||||
|
||||
### Supported hardware combinations
|
||||
|
||||
- ESP32 based device with a CC1101 transceiver
|
||||
- Heltec WiFi LoRa 32 (V2.1)
|
||||
|
||||
### Supported Decoders
|
||||
|
||||
```
|
||||
Registering protocol [2] "Acurite 609TXC Temperature and Humidity Sensor"
|
||||
@@ -254,75 +261,80 @@ Registering protocol [4] "Acurite 986 Refrigerator / Freezer Thermometer"
|
||||
Registering protocol [5] "Acurite 606TX Temperature Sensor"
|
||||
Registering protocol [6] "Acurite 00275rm,00276rm Temp/Humidity with optional probe"
|
||||
Registering protocol [7] "Acurite 590TX Temperature with optional Humidity"
|
||||
Registering protocol [8] "Akhan 100F14 remote keyless entry"
|
||||
Registering protocol [9] "AlectoV1 Weather Sensor (Alecto WS3500 WS4500 Ventus W155/W044 Oregon)"
|
||||
Registering protocol [10] "Ambient Weather TX-8300 Temperature/Humidity Sensor"
|
||||
Registering protocol [11] "Auriol AFW2A1 temperature/humidity sensor"
|
||||
Registering protocol [12] "Auriol HG02832, HG05124A-DCF, Rubicson 48957 temperature/humidity sensor"
|
||||
Registering protocol [13] "BlueLine Power Monitor"
|
||||
Registering protocol [14] "Blyss DC5-UK-WH"
|
||||
Registering protocol [16] "Bresser Thermo-/Hygro-Sensor 3CH"
|
||||
Registering protocol [18] "Burnhard BBQ thermometer"
|
||||
Registering protocol [19] "Calibeur RF-104 Sensor"
|
||||
Registering protocol [20] "Cardin S466-TX2"
|
||||
Registering protocol [21] "Chuango Security Technology"
|
||||
Registering protocol [22] "Companion WTR001 Temperature Sensor"
|
||||
Registering protocol [25] "Ecowitt Wireless Outdoor Thermometer WH53/WH0280/WH0281A"
|
||||
Registering protocol [26] "Eurochron EFTH-800 temperature and humidity sensor"
|
||||
Registering protocol [30] "Esperanza EWS"
|
||||
Registering protocol [32] "Fine Offset Electronics, WH2, WH5, Telldus Temperature/Humidity/Rain Sensor"
|
||||
Registering protocol [33] "Fine Offset Electronics, WH0530 Temperature/Rain Sensor"
|
||||
Registering protocol [34] "Fine Offset WH1050 Weather Station"
|
||||
Registering protocol [35] "Fine Offset Electronics WH1080/WH3080 Weather Station"
|
||||
Registering protocol [37] "FT-004-B Temperature Sensor"
|
||||
Registering protocol [38] "Generic wireless motion sensor"
|
||||
Registering protocol [39] "Generic Remote SC226x EV1527"
|
||||
Registering protocol [40] "Generic temperature sensor 1"
|
||||
Registering protocol [41] "Globaltronics QUIGG GT-TMBBQ-05"
|
||||
Registering protocol [42] "Globaltronics GT-WT-02 Sensor"
|
||||
Registering protocol [43] "Globaltronics GT-WT-03 Sensor"
|
||||
Registering protocol [44] "Microchip HCS200 KeeLoq Hopping Encoder based remotes"
|
||||
Registering protocol [45] "Honeywell ActivLink, Wireless Doorbell"
|
||||
Registering protocol [46] "HT680 Remote control"
|
||||
Registering protocol [47] "inFactory, nor-tec, FreeTec NC-3982-913 temperature humidity sensor"
|
||||
Registering protocol [49] "Interlogix GE UTC Security Devices"
|
||||
Registering protocol [51] "Kedsum Temperature & Humidity Sensor, Pearl NC-7415"
|
||||
Registering protocol [52] "Kerui PIR / Contact Sensor"
|
||||
Registering protocol [53] "LaCrosse TX Temperature / Humidity Sensor"
|
||||
Registering protocol [54] "LaCrosse TX141-Bv2, TX141TH-Bv2, TX141-Bv3, TX141W, TX145wsdth sensor"
|
||||
Registering protocol [55] "LaCrosse/ELV/Conrad WS7000/WS2500 weather sensors"
|
||||
Registering protocol [56] "LaCrosse WS-2310 / WS-3600 Weather Station"
|
||||
Registering protocol [58] "Maverick et73"
|
||||
Registering protocol [60] "Missil ML0757 weather station"
|
||||
Registering protocol [64] "Nexus, FreeTec NC-7345, NX-3980, Solight TE82S, TFA 30.3209 temperature/humidity sensor"
|
||||
Registering protocol [66] "Opus/Imagintronix XT300 Soil Moisture"
|
||||
Registering protocol [67] "Oregon Scientific SL109H Remote Thermal Hygro Sensor"
|
||||
Registering protocol [69] "Philips outdoor temperature sensor (type AJ3650)"
|
||||
Registering protocol [70] "Philips outdoor temperature sensor (type AJ7010)"
|
||||
Registering protocol [71] "Prologue, FreeTec NC-7104, NC-7159-675 temperature sensor"
|
||||
Registering protocol [73] "Quhwa"
|
||||
Registering protocol [75] "Rubicson Temperature Sensor"
|
||||
Registering protocol [76] "Rubicson 48659 Thermometer"
|
||||
Registering protocol [77] "Conrad S3318P, FreeTec NC-5849-913 temperature humidity sensor"
|
||||
Registering protocol [78] "Silvercrest Remote Control"
|
||||
Registering protocol [79] "Skylink HA-434TL motion sensor"
|
||||
Registering protocol [80] "Wireless Smoke and Heat Detector GS 558"
|
||||
Registering protocol [81] "Solight TE44/TE66, EMOS E0107T, NX-6876-917"
|
||||
Registering protocol [82] "Springfield Temperature and Soil Moisture"
|
||||
Registering protocol [83] "TFA Dostmann 30.3221.02 T/H Outdoor Sensor"
|
||||
Registering protocol [84] "TFA Drop Rain Gauge 30.3233.01"
|
||||
Registering protocol [85] "TFA pool temperature sensor"
|
||||
Registering protocol [86] "TFA-Twin-Plus-30.3049, Conrad KW9010, Ea2 BL999"
|
||||
Registering protocol [87] "Thermopro TP11 Thermometer"
|
||||
Registering protocol [88] "Thermopro TP08/TP12/TP20 thermometer"
|
||||
Registering protocol [90] "TS-FT002 Wireless Ultrasonic Tank Liquid Level Meter With Temperature Sensor"
|
||||
Registering protocol [91] "Visonic powercode"
|
||||
Registering protocol [92] "Waveman Switch Transmitter"
|
||||
Registering protocol [93] "WG-PB12V1 Temperature Sensor"
|
||||
Registering protocol [94] "WS2032 weather station"
|
||||
Registering protocol [95] "Hyundai WS SENZOR Remote Temperature Sensor"
|
||||
Registering protocol [96] "WT0124 Pool Thermometer"
|
||||
Registering protocol [98] "X10 Security"
|
||||
Registering protocol [8] "Acurite Grill/Meat Thermometer 01185M"
|
||||
Registering protocol [9] "Akhan 100F14 remote keyless entry"
|
||||
Registering protocol [10] "AlectoV1 Weather Sensor (Alecto WS3500 WS4500 Ventus W155/W044 Oregon)"
|
||||
Registering protocol [11] "Ambient Weather TX-8300 Temperature/Humidity Sensor"
|
||||
Registering protocol [13] "Auriol AFT 77 B2 temperature sensor"
|
||||
Registering protocol [14] "Auriol AFW2A1 temperature/humidity sensor"
|
||||
Registering protocol [15] "Auriol AHFL temperature/humidity sensor"
|
||||
Registering protocol [16] "Auriol HG02832, HG05124A-DCF, Rubicson 48957 temperature/humidity sensor"
|
||||
Registering protocol [18] "Blyss DC5-UK-WH"
|
||||
Registering protocol [20] "Bresser Thermo-/Hygro-Sensor 3CH"
|
||||
Registering protocol [22] "Burnhard BBQ thermometer"
|
||||
Registering protocol [23] "Calibeur RF-104 Sensor"
|
||||
Registering protocol [24] "Cardin S466-TX2"
|
||||
Registering protocol [25] "Chuango Security Technology"
|
||||
Registering protocol [26] "Companion WTR001 Temperature Sensor"
|
||||
Registering protocol [29] "Ecowitt Wireless Outdoor Thermometer WH53/WH0280/WH0281A"
|
||||
Registering protocol [30] "Eurochron EFTH-800 temperature and humidity sensor"
|
||||
Registering protocol [34] "Esperanza EWS"
|
||||
Registering protocol [36] "Fine Offset Electronics, WH2, WH5, Telldus Temperature/Humidity/Rain Sensor"
|
||||
Registering protocol [37] "Fine Offset Electronics, WH0530 Temperature/Rain Sensor"
|
||||
Registering protocol [38] "Fine Offset WH1050 Weather Station"
|
||||
Registering protocol [39] "Fine Offset Electronics WH1080/WH3080 Weather Station"
|
||||
Registering protocol [41] "FT-004-B Temperature Sensor"
|
||||
Registering protocol [42] "Generic wireless motion sensor"
|
||||
Registering protocol [43] "Generic Remote SC226x EV1527"
|
||||
Registering protocol [44] "Generic temperature sensor 1"
|
||||
Registering protocol [45] "Govee Water Leak Dectector H5054, Door Contact Sensor B5023"
|
||||
Registering protocol [46] "Globaltronics QUIGG GT-TMBBQ-05"
|
||||
Registering protocol [47] "Globaltronics GT-WT-02 Sensor"
|
||||
Registering protocol [48] "Globaltronics GT-WT-03 Sensor"
|
||||
Registering protocol [49] "Microchip HCS200 KeeLoq Hopping Encoder based remotes"
|
||||
Registering protocol [50] "Honeywell ActivLink, Wireless Doorbell"
|
||||
Registering protocol [51] "HT680 Remote control"
|
||||
Registering protocol [52] "inFactory, nor-tec, FreeTec NC-3982-913 temperature humidity sensor"
|
||||
Registering protocol [54] "Interlogix GE UTC Security Devices"
|
||||
Registering protocol [56] "Kedsum Temperature & Humidity Sensor, Pearl NC-7415"
|
||||
Registering protocol [57] "Kerui PIR / Contact Sensor"
|
||||
Registering protocol [58] "LaCrosse TX Temperature / Humidity Sensor"
|
||||
Registering protocol [59] "LaCrosse TX141-Bv2, TX141TH-Bv2, TX141-Bv3, TX141W, TX145wsdth sensor"
|
||||
Registering protocol [60] "LaCrosse/ELV/Conrad WS7000/WS2500 weather sensors"
|
||||
Registering protocol [61] "LaCrosse WS-2310 / WS-3600 Weather Station"
|
||||
Registering protocol [63] "Markisol, E-Motion, BOFU, Rollerhouse, BF-30x, BF-415 curtain remote"
|
||||
Registering protocol [64] "Maverick et73"
|
||||
Registering protocol [66] "Missil ML0757 weather station"
|
||||
Registering protocol [68] "Nexus, FreeTec NC-7345, NX-3980, Solight TE82S, TFA 30.3209 temperature/humidity sensor"
|
||||
Registering protocol [70] "Opus/Imagintronix XT300 Soil Moisture"
|
||||
Registering protocol [71] "Oregon Scientific SL109H Remote Thermal Hygro Sensor"
|
||||
Registering protocol [73] "Philips outdoor temperature sensor (type AJ3650)"
|
||||
Registering protocol [74] "Philips outdoor temperature sensor (type AJ7010)"
|
||||
Registering protocol [75] "Prologue, FreeTec NC-7104, NC-7159-675 temperature sensor"
|
||||
Registering protocol [76] "Quhwa"
|
||||
Registering protocol [78] "Rubicson Temperature Sensor"
|
||||
Registering protocol [79] "Rubicson 48659 Thermometer"
|
||||
Registering protocol [80] "Conrad S3318P, FreeTec NC-5849-913 temperature humidity sensor"
|
||||
Registering protocol [81] "Silvercrest Remote Control"
|
||||
Registering protocol [82] "Skylink HA-434TL motion sensor"
|
||||
Registering protocol [83] "Wireless Smoke and Heat Detector GS 558"
|
||||
Registering protocol [84] "Solight TE44/TE66, EMOS E0107T, NX-6876-917"
|
||||
Registering protocol [85] "Springfield Temperature and Soil Moisture"
|
||||
Registering protocol [86] "TFA Dostmann 30.3221.02 T/H Outdoor Sensor"
|
||||
Registering protocol [87] "TFA Drop Rain Gauge 30.3233.01"
|
||||
Registering protocol [88] "TFA pool temperature sensor"
|
||||
Registering protocol [89] "TFA-Twin-Plus-30.3049, Conrad KW9010, Ea2 BL999"
|
||||
Registering protocol [90] "Thermopro TP11 Thermometer"
|
||||
Registering protocol [91] "Thermopro TP08/TP12/TP20 thermometer"
|
||||
Registering protocol [93] "TS-FT002 Wireless Ultrasonic Tank Liquid Level Meter With Temperature Sensor"
|
||||
Registering protocol [94] "Visonic powercode"
|
||||
Registering protocol [95] "Waveman Switch Transmitter"
|
||||
Registering protocol [96] "WG-PB12V1 Temperature Sensor"
|
||||
Registering protocol [97] "WS2032 weather station"
|
||||
Registering protocol [98] "Hyundai WS SENZOR Remote Temperature Sensor"
|
||||
Registering protocol [99] "WT0124 Pool Thermometer"
|
||||
Registering protocol [100] "X10 RF"
|
||||
Registering protocol [101] "X10 Security"
|
||||
```
|
||||
|
||||
### Change receive frequency
|
||||
@@ -331,17 +343,12 @@ Default receive frequency of the CC1101 module is 433.92 Mhz, and this can be ca
|
||||
|
||||
`home/OpenMQTTGateway/commands/MQTTtoRTL_433 {"mhz":315.026}`
|
||||
|
||||
### Minimum Signal Strength
|
||||
### Change Signal RSSI Threshold Delta
|
||||
|
||||
Default minimum signal strength to enable the receiver is -82, and this setting can be changed with the following command.
|
||||
Delta applied to RSSI floor noise level to determine start and end of signal, defaults to 9db.
|
||||
|
||||
`home/OpenMQTTGateway/commands/MQTTtoRTL_433 {"rssi":-75}`
|
||||
`home/OpenMQTTGateway/commands/MQTTtoRTL_433 {"rssi": 9}`
|
||||
|
||||
### Enable rtl_433 device decoder verbose debug
|
||||
|
||||
This function does not work when all available decoders are enabled and triggers an out of memory restart.
|
||||
|
||||
`home/OpenMQTTGateway/commands/MQTTtoRTL_433 {"debug":4}`
|
||||
|
||||
### Retrieve current status of receiver
|
||||
|
||||
@@ -353,13 +360,16 @@ This function does not work when all available decoders are enabled and triggers
|
||||
"debug":0, - rtl_433 verbose setting
|
||||
"duration":11799327, - duration of current signal
|
||||
"Gap length":-943575, - duration of gap between current signal
|
||||
"signalRssi":-38, - most recent received signal strength
|
||||
"rssi":-38, - most recent received signal strength
|
||||
"train":1, - signal processing train #
|
||||
"messageCount":3, - total number of signals received
|
||||
"totalSignals":9, - RegOokFix signal quality count ( of 10 )
|
||||
"ignoredSignals":0, - RegOokFix signal quality ignored signals
|
||||
"unparsedSignals":3, - RegOokFix signal quality unparseable signals
|
||||
"_enabledReceiver":1, - which receiver is enabled
|
||||
"receiveMode":0, - is the receiver currently receiving a signal
|
||||
"currentRssi":-89, - current rssi level
|
||||
"minimumRssi":-82, - minimum rssi level to start signal processing
|
||||
"rssiThreshold":-82, - minimum rssi level to start signal processing
|
||||
"pulses":0, - how many pulses have been received in the current signal
|
||||
"StackHighWaterMark":5528, - ESP32 Stack
|
||||
"freeMem":112880} - ESP32 memory available
|
||||
|
||||
Reference in new issue
Block a user