correct RF2 keys
https://community.openmqttgateway.com/t/kaku-acd-1000-and-flamingo-sf-501p-switch-dont-respond-on-omg-rf2-sent-signal/438/7?u=1technophile
This commit is contained in:
1 parent
650d0877ab
commit
a11e336215
2 files changed
+3
-3
No files matched your search
+2
-2
@@ -220,10 +220,10 @@ void rf2Callback(unsigned int period, unsigned long address, unsigned long group
|
||||
if (boolSWITCHTYPE != 99) {
|
||||
trc(F("MQTTtoRF2 switch type ok"));
|
||||
bool isDimCommand = boolSWITCHTYPE == 2;
|
||||
unsigned long valueCODE = RF2data["adress"];
|
||||
unsigned long valueCODE = RF2data["address"];
|
||||
int valueUNIT = RF2data["unit"] | -1;
|
||||
int valuePERIOD = RF2data["period"];
|
||||
int valueGROUP = RF2data["groupBit"];
|
||||
int valueGROUP = RF2data["group"];
|
||||
int valueDIM = RF2data["dim"] | -1;
|
||||
if ((valueCODE != 0) || (valueUNIT != -1)|| (valuePERIOD != 0)){
|
||||
trc(F("MQTTtoRF2"));
|
||||
|
||||
+1
-1
@@ -53,7 +53,7 @@ RF supported protocols
|
||||
#define subjectMQTTtoRF2 Base_Topic Gateway_Name "/commands/MQTTtoRF2"
|
||||
#define subjectRF2toMQTT Base_Topic Gateway_Name "/RF2toMQTT"
|
||||
#define subjectGTWRF2toMQTT Base_Topic Gateway_Name "/433toMQTT"
|
||||
#define RF2codeKey "CODE_" // code will be defined if a subject contains RF2codeKey followed by a value of 7 digits
|
||||
#define RF2codeKey "ADDRESS_" // code will be defined if a subject contains RF2codeKey followed by a value of 7 digits
|
||||
#define RF2periodKey "PERIOD_" // period will be defined if a subject contains RF2periodKey followed by a value of 3 digits
|
||||
#define RF2unitKey "UNIT_" // number of your unit value will be defined if a subject contains RF2unitKey followed by a value of 1-2 digits
|
||||
#define RF2groupKey "GROUP_" // number of your group value will be defined if a subject contains RF2groupKey followed by a value of 1 digit
|
||||
|
||||
Reference in new issue