155 lines
4.7 KiB
C++
155 lines
4.7 KiB
C++
//-----------------------------------------------------------------------------
|
|
//
|
|
// ThermostatOperatingState.cpp
|
|
//
|
|
// Implementation of the Z-Wave COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
|
|
//
|
|
// Copyright (c) 2010 Mal Lansell <openzwave@lansell.org>
|
|
//
|
|
// SOFTWARE NOTICE AND LICENSE
|
|
//
|
|
// This file is part of OpenZWave.
|
|
//
|
|
// OpenZWave is free software: you can redistribute it and/or modify
|
|
// it under the terms of the GNU Lesser General Public License as published
|
|
// by the Free Software Foundation, either version 3 of the License,
|
|
// or (at your option) any later version.
|
|
//
|
|
// OpenZWave is distributed in the hope that it will be useful,
|
|
// but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
// GNU Lesser General Public License for more details.
|
|
//
|
|
// You should have received a copy of the GNU Lesser General Public License
|
|
// along with OpenZWave. If not, see <http://www.gnu.org/licenses/>.
|
|
//
|
|
//-----------------------------------------------------------------------------
|
|
|
|
#include "CommandClasses.h"
|
|
#include "ThermostatOperatingState.h"
|
|
#include "../Defs.h"
|
|
#include "../Msg.h"
|
|
#include "../Node.h"
|
|
#include "../Driver.h"
|
|
#include "../platform/Log.h"
|
|
|
|
#include "../value_classes/ValueString.h"
|
|
|
|
using namespace OpenZWave;
|
|
|
|
enum ThermostatOperatingStateCmd
|
|
{
|
|
ThermostatOperatingStateCmd_Get = 0x02,
|
|
ThermostatOperatingStateCmd_Report = 0x03
|
|
};
|
|
|
|
static char const* c_stateName[] =
|
|
{
|
|
"Idle",
|
|
"Heating",
|
|
"Cooling",
|
|
"Fan Only",
|
|
"Pending Heat",
|
|
"Pending Cool",
|
|
"Vent / Economizer",
|
|
"State 07", // Undefined states. May be used in the future.
|
|
"State 08",
|
|
"State 09",
|
|
"State 10",
|
|
"State 11",
|
|
"State 12",
|
|
"State 13",
|
|
"State 14",
|
|
"State 15"
|
|
};
|
|
|
|
//-----------------------------------------------------------------------------
|
|
// <ThermostatOperatingState::RequestState>
|
|
// Get the static thermostat mode details from the device
|
|
//-----------------------------------------------------------------------------
|
|
bool ThermostatOperatingState::RequestState
|
|
(
|
|
uint32 const _requestFlags,
|
|
uint8 const _instance,
|
|
Driver::MsgQueue const _queue
|
|
)
|
|
{
|
|
if( _requestFlags & RequestFlag_Dynamic )
|
|
{
|
|
return RequestValue( _requestFlags, 0, _instance, _queue );
|
|
}
|
|
return false;
|
|
}
|
|
|
|
//-----------------------------------------------------------------------------
|
|
// <ThermostatOperatingState::RequestValue>
|
|
// Get a thermostat mode value from the device
|
|
//-----------------------------------------------------------------------------
|
|
bool ThermostatOperatingState::RequestValue
|
|
(
|
|
uint32 const _requestFlags,
|
|
uint8 const _dummy1, // = 0 (not used)
|
|
uint8 const _instance,
|
|
Driver::MsgQueue const _queue
|
|
)
|
|
{
|
|
if ( IsGetSupported() )
|
|
{
|
|
Msg* msg = new Msg( "ThermostatOperatingStateCmd_Get", GetNodeId(), REQUEST, FUNC_ID_ZW_SEND_DATA, true, true, FUNC_ID_APPLICATION_COMMAND_HANDLER, GetCommandClassId() );
|
|
msg->SetInstance( this, _instance );
|
|
msg->Append( GetNodeId() );
|
|
msg->Append( 2 );
|
|
msg->Append( GetCommandClassId() );
|
|
msg->Append( ThermostatOperatingStateCmd_Get );
|
|
msg->Append( GetDriver()->GetTransmitOptions() );
|
|
GetDriver()->SendMsg( msg, _queue );
|
|
return true;
|
|
} else {
|
|
Log::Write( LogLevel_Info, GetNodeId(), "ThermostatOperatingStateCmd_Get Not Supported on this node");
|
|
}
|
|
return false;
|
|
}
|
|
|
|
//-----------------------------------------------------------------------------
|
|
// <ThermostatOperatingState::HandleMsg>
|
|
// Handle a message from the Z-Wave network
|
|
//-----------------------------------------------------------------------------
|
|
bool ThermostatOperatingState::HandleMsg
|
|
(
|
|
uint8 const* _data,
|
|
uint32 const _length,
|
|
uint32 const _instance // = 1
|
|
)
|
|
{
|
|
if( ThermostatOperatingStateCmd_Report == (ThermostatOperatingStateCmd)_data[0] )
|
|
{
|
|
// We have received the thermostat operating state from the Z-Wave device
|
|
if( ValueString* valueString = static_cast<ValueString*>( GetValue( _instance, 0 ) ) )
|
|
{
|
|
/* no need bounds checking on c_stateName here, as it can only be 1 Byte anyway */
|
|
valueString->OnValueRefreshed( c_stateName[_data[1]&0x0f] );
|
|
valueString->Release();
|
|
Log::Write( LogLevel_Info, GetNodeId(), "Received thermostat operating state: %s", valueString->GetValue().c_str() );
|
|
}
|
|
return true;
|
|
}
|
|
|
|
return false;
|
|
}
|
|
|
|
//-----------------------------------------------------------------------------
|
|
// <ThermostatOperatingState::CreateVars>
|
|
// Create the values managed by this command class
|
|
//-----------------------------------------------------------------------------
|
|
void ThermostatOperatingState::CreateVars
|
|
(
|
|
uint8 const _instance
|
|
)
|
|
{
|
|
if( Node* node = GetNodeUnsafe() )
|
|
{
|
|
node->CreateValueString( ValueID::ValueGenre_User, GetCommandClassId(), _instance, 0, "Operating State", "", true, false, c_stateName[0], 0 );
|
|
}
|
|
}
|
|
|