116 lines
5.3 KiB
ReStructuredText
116 lines
5.3 KiB
ReStructuredText
.. |yes| image:: ../../images/yes.png
|
|
.. |no| image:: ../../images/no.png
|
|
|
|
.. role:: underline
|
|
:class: underline
|
|
|
|
+------------------+-------------+
|
|
| **Feature** | **Support** |
|
|
+------------------+-------------+
|
|
| Sending | |no| |
|
|
+------------------+-------------+
|
|
| Receiving | |yes| |
|
|
+------------------+-------------+
|
|
| Config | |yes| |
|
|
+------------------+-------------+
|
|
|
|
.. rubric:: Supported Brands
|
|
|
|
+------------------+--------------+
|
|
| **Brand** | **Protocol** |
|
|
+------------------+--------------+
|
|
| BMP180 | bmp180 |
|
|
+------------------+--------------+
|
|
| BMP085 | bmp085 |
|
|
+------------------+--------------+
|
|
|
|
.. rubric:: Sender Arguments
|
|
|
|
*None*
|
|
|
|
.. rubric:: Config
|
|
|
|
.. code-block:: json
|
|
:linenos:
|
|
|
|
{
|
|
"devices": {
|
|
"bmp180": {
|
|
"protocol": [ "bmp180" ],
|
|
"id": [{
|
|
"id": "0x77"
|
|
}],
|
|
"temperature": 19.1,
|
|
"pressure": 1006.8,
|
|
"oversampling": 1
|
|
}
|
|
},
|
|
"gui": {
|
|
"temperature": {
|
|
"name": "Temperature Sensor",
|
|
"group": [ "Misc" ],
|
|
"media": [ "all" ]
|
|
}
|
|
}
|
|
}
|
|
|
|
+------------------+------------------+
|
|
| **Option** | **Value** |
|
|
+------------------+------------------+
|
|
| id | *valid i2c path* |
|
|
+------------------+------------------+
|
|
| temperature | -40 - 85 |
|
|
+------------------+------------------+
|
|
| pressure | 300 - 1100 |
|
|
+------------------+------------------+
|
|
| oversampling | 0 - 3 |
|
|
+------------------+------------------+
|
|
|
|
.. rubric:: Optional Settings
|
|
|
|
:underline:`Device Settings`
|
|
|
|
+--------------------+-------------+------------+-------------------------------------------------+
|
|
| **Setting** | **Default** | **Format** | **Description** |
|
|
+--------------------+-------------+------------+-------------------------------------------------+
|
|
| poll-interval | 10 | seconds | What should be the poll interval of the sensors |
|
|
+--------------------+-------------+------------+-------------------------------------------------+
|
|
| humidity-offset | 0 | number | Correct humidity value |
|
|
+--------------------+-------------+------------+-------------------------------------------------+
|
|
| temperature-offset | 0 | number | Correct temperature value |
|
|
+--------------------+-------------+------------+-------------------------------------------------+
|
|
|
|
:underline:`GUI Settings`
|
|
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
| **Setting** | **Default** | **Format** | **Description** |
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
| temperature-decimals | 2 | number | How many decimals the GUIs should display for temperature |
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
| pressure-decimals | 2 | number | How many decimals the GUIs should display for pressure |
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
| show-temperature | 1 | 1 or 0 | Don't display the temperature value |
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
| show-pressure | 1 | 1 or 0 | Don't display the pressure value |
|
|
+----------------------+-------------+------------+-----------------------------------------------------------+
|
|
|
|
.. rubric:: Comments
|
|
|
|
Pressure is provided in hectopascal (hPa) and temperature in degrees Celsius (°C).
|
|
|
|
Option ``oversampling`` sets the BMP180 hardware accuracy mode which is relevant for pressure readings only.
|
|
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
| Mode | oversampling | Internal no. of samples | Conversion time pressure max. [ms] |
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
| ultra low power | 0 | 1 | 4.5 |
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
| standard | 1 | 2 | 7.5 |
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
| high resolution | 2 | 4 | 13.5 |
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
| ultra high resolution | 3 | 8 | 25.5 |
|
|
+-----------------------+--------------+-------------------------+------------------------------------+
|
|
|
|