Manual control with a button press triggered the relay but 2 times (when pressing and releasing), fixing this. Check that we have two consecutive readings of temperature above the threshold to trigger the actuator to OFF And remove it by default to the shelly, as I see unjustified jumps of temperature above 80C.
146 lines
5.3 KiB
Arduino
146 lines
5.3 KiB
Arduino
/*
|
|
OpenMQTTGateway Addon - ESP8266 or Arduino program for home automation
|
|
|
|
Act as a wifi or ethernet gateway between your 433mhz/infrared IR signal and a MQTT broker
|
|
Send and receiving command by MQTT
|
|
|
|
Output GPIO defined to High or Low
|
|
|
|
Copyright: (c)Florian ROBERT
|
|
|
|
Contributors:
|
|
- 1technophile
|
|
|
|
This file is part of OpenMQTTGateway.
|
|
|
|
OpenMQTTGateway is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
OpenMQTTGateway is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
#include "User_config.h"
|
|
|
|
#ifdef ZactuatorONOFF
|
|
unsigned long timeinttemp = 0;
|
|
|
|
void setupONOFF() {
|
|
pinMode(ACTUATOR_ONOFF_GPIO, OUTPUT);
|
|
# ifdef ACTUATOR_ONOFF_DEFAULT
|
|
digitalWrite(ACTUATOR_ONOFF_GPIO, ACTUATOR_ONOFF_DEFAULT);
|
|
# endif
|
|
}
|
|
|
|
# if jsonReceiving
|
|
void MQTTtoONOFF(char* topicOri, JsonObject& ONOFFdata) {
|
|
if (cmpToMainTopic(topicOri, subjectMQTTtoONOFF)) {
|
|
Log.trace(F("MQTTtoONOFF json data analysis" CR));
|
|
int boolSWITCHTYPE = ONOFFdata["cmd"] | 99;
|
|
int gpio = ONOFFdata["gpio"] | ACTUATOR_ONOFF_GPIO;
|
|
if (boolSWITCHTYPE != 99) {
|
|
Log.notice(F("MQTTtoONOFF boolSWITCHTYPE ok: %d" CR), boolSWITCHTYPE);
|
|
Log.notice(F("GPIO number: %d" CR), gpio);
|
|
pinMode(gpio, OUTPUT);
|
|
digitalWrite(gpio, boolSWITCHTYPE);
|
|
// we acknowledge the sending by publishing the value to an acknowledgement topic
|
|
pub(subjectGTWONOFFtoMQTT, ONOFFdata);
|
|
} else {
|
|
if (ONOFFdata["cmd"] == "high_pulse") {
|
|
Log.notice(F("MQTTtoONOFF high_pulse ok" CR));
|
|
Log.notice(F("GPIO number: %d" CR), gpio);
|
|
int pulselength = ONOFFdata["pulse_length"] | 500;
|
|
Log.notice(F("Pulse length: %d ms" CR), pulselength);
|
|
pinMode(gpio, OUTPUT);
|
|
digitalWrite(gpio, HIGH);
|
|
delay(pulselength);
|
|
digitalWrite(gpio, LOW);
|
|
} else if (ONOFFdata["cmd"] == "low_pulse") {
|
|
Log.notice(F("MQTTtoONOFF low_pulse ok" CR));
|
|
Log.notice(F("GPIO number: %d" CR), gpio);
|
|
int pulselength = ONOFFdata["pulse_length"] | 500;
|
|
Log.notice(F("Pulse length: %d ms" CR), pulselength);
|
|
pinMode(gpio, OUTPUT);
|
|
digitalWrite(gpio, LOW);
|
|
delay(pulselength);
|
|
digitalWrite(gpio, HIGH);
|
|
} else {
|
|
Log.error(F("MQTTtoONOFF failed json read" CR));
|
|
}
|
|
}
|
|
}
|
|
}
|
|
# endif
|
|
|
|
# if simpleReceiving
|
|
void MQTTtoONOFF(char* topicOri, char* datacallback) {
|
|
if ((cmpToMainTopic(topicOri, subjectMQTTtoONOFF))) {
|
|
Log.trace(F("MQTTtoONOFF" CR));
|
|
char* endptr = NULL;
|
|
long gpio = strtol(datacallback, &endptr, 10);
|
|
if (datacallback == endptr)
|
|
gpio = ACTUATOR_ONOFF_GPIO;
|
|
|
|
Log.notice(F("GPIO number: %d" CR), gpio);
|
|
pinMode(gpio, OUTPUT);
|
|
|
|
bool ON = false;
|
|
if (strstr(topicOri, ONKey) != NULL)
|
|
ON = true;
|
|
if (strstr(topicOri, OFFKey) != NULL)
|
|
ON = false;
|
|
|
|
digitalWrite(gpio, ON);
|
|
// we acknowledge the sending by publishing the value to an acknowledgement topic
|
|
char b = ON;
|
|
pub(subjectGTWONOFFtoMQTT, &b);
|
|
}
|
|
}
|
|
# endif
|
|
|
|
//Check regularly temperature of the ESP32 board and switch OFF the relay if temperature is more than MAX_TEMP_ACTUATOR
|
|
# ifdef MAX_TEMP_ACTUATOR
|
|
void OverHeatingRelayOFF() {
|
|
# if defined(ESP32) && !defined(NO_INT_TEMP_READING)
|
|
if (millis() > (timeinttemp + TimeBetweenReadingIntTemp)) {
|
|
static float previousInternalTempc = 0;
|
|
float internalTempc = intTemperatureRead();
|
|
Log.trace(F("Internal temperature of the ESP32 %F" CR), internalTempc);
|
|
// We switch OFF the actuator if the temperature of the ESP32 is more than MAX_TEMP_ACTUATOR two consecutive times, so as to avoid false single readings to trigger the relay OFF.
|
|
if (internalTempc > MAX_TEMP_ACTUATOR && previousInternalTempc > MAX_TEMP_ACTUATOR && digitalRead(ACTUATOR_ONOFF_GPIO) == ACTUATOR_ON) {
|
|
Log.error(F("[ActuatorONOFF] OverTemperature detected ( %F > %F ) switching OFF Actuator" CR), internalTempc, MAX_TEMP_ACTUATOR);
|
|
ActuatorTrigger();
|
|
}
|
|
previousInternalTempc = internalTempc;
|
|
timeinttemp = millis();
|
|
}
|
|
# endif
|
|
}
|
|
# else
|
|
void OverHeatingRelayOFF() {}
|
|
# endif
|
|
|
|
/*
|
|
Handling of actuator control following the cases below:
|
|
-Button press, if the button goes to ACTUATOR_BUTTON_TRIGGER_LEVEL we change the Actuator level
|
|
-Status less switch state change (a switch without ON OFF labels), an action of this type of switch will trigger a change of the actuator state independently from the switch position
|
|
*/
|
|
void ActuatorTrigger() {
|
|
uint8_t level = !digitalRead(ACTUATOR_ONOFF_GPIO);
|
|
Log.trace(F("Actuator triggered %d" CR), level);
|
|
digitalWrite(ACTUATOR_ONOFF_GPIO, level);
|
|
// Send the state of the switch to the broker so as to update the status
|
|
StaticJsonDocument<JSON_MSG_BUFFER> jsonBuffer;
|
|
JsonObject ONOFFdata = jsonBuffer.to<JsonObject>();
|
|
ONOFFdata["cmd"] = (int)level;
|
|
pub(subjectGTWONOFFtoMQTT, ONOFFdata);
|
|
}
|
|
|
|
#endif
|