Fix actuator manual control with button press and overheat protection (#1403)
Manual control with a button press triggered the relay but 2 times (when pressing and releasing), fixing this. Check that we have two consecutive readings of temperature above the threshold to trigger the actuator to OFF And remove it by default to the shelly, as I see unjustified jumps of temperature above 80C.
This commit is contained in:
1 parent
76724240f4
commit
b4003d4ea1
4 files changed
+28
-17
No files matched your search
@@ -89,7 +89,14 @@ void MeasureGPIOInput() {
|
||||
|
||||
# if defined(ZactuatorONOFF) && defined(ACTUATOR_TRIGGER)
|
||||
//Trigger the actuator if we are not at startup
|
||||
if (InputState != 3) ActuatorManualTrigger(InputState);
|
||||
if (InputState != 3) {
|
||||
# if defined(ACTUATOR_BUTTON_TRIGGER_LEVEL)
|
||||
if (InputState == ACTUATOR_BUTTON_TRIGGER_LEVEL)
|
||||
ActuatorTrigger(); // Button press trigger
|
||||
# else
|
||||
ActuatorTrigger(); // Switch trigger
|
||||
# endif
|
||||
}
|
||||
# endif
|
||||
InputState = reading;
|
||||
}
|
||||
|
||||
Reference in new issue