Fix actuator manual control with button press and overheat protection (#1403)
Manual control with a button press triggered the relay but 2 times (when pressing and releasing), fixing this. Check that we have two consecutive readings of temperature above the threshold to trigger the actuator to OFF And remove it by default to the shelly, as I see unjustified jumps of temperature above 80C.
This commit is contained in:
1 parent
76724240f4
commit
b4003d4ea1
4 files changed
+28
-17
No files matched your search
+12
-11
@@ -109,12 +109,15 @@ void MQTTtoONOFF(char* topicOri, char* datacallback) {
|
||||
void OverHeatingRelayOFF() {
|
||||
# if defined(ESP32) && !defined(NO_INT_TEMP_READING)
|
||||
if (millis() > (timeinttemp + TimeBetweenReadingIntTemp)) {
|
||||
static float previousInternalTempc = 0;
|
||||
float internalTempc = intTemperatureRead();
|
||||
Log.trace(F("Internal temperature of the ESP32 %F" CR), internalTempc);
|
||||
if (internalTempc > MAX_TEMP_ACTUATOR && digitalRead(ACTUATOR_ONOFF_GPIO) == ACTUATOR_ON) {
|
||||
// We switch OFF the actuator if the temperature of the ESP32 is more than MAX_TEMP_ACTUATOR two consecutive times, so as to avoid false single readings to trigger the relay OFF.
|
||||
if (internalTempc > MAX_TEMP_ACTUATOR && previousInternalTempc > MAX_TEMP_ACTUATOR && digitalRead(ACTUATOR_ONOFF_GPIO) == ACTUATOR_ON) {
|
||||
Log.error(F("[ActuatorONOFF] OverTemperature detected ( %F > %F ) switching OFF Actuator" CR), internalTempc, MAX_TEMP_ACTUATOR);
|
||||
ActuatorManualTrigger(!ACTUATOR_ON);
|
||||
ActuatorTrigger();
|
||||
}
|
||||
previousInternalTempc = internalTempc;
|
||||
timeinttemp = millis();
|
||||
}
|
||||
# endif
|
||||
@@ -123,15 +126,13 @@ void OverHeatingRelayOFF() {
|
||||
void OverHeatingRelayOFF() {}
|
||||
# endif
|
||||
|
||||
void ActuatorManualTrigger(uint8_t level) {
|
||||
# ifdef ACTUATOR_BUTTON_TRIGGER_LEVEL
|
||||
if (level == ACTUATOR_BUTTON_TRIGGER_LEVEL) {
|
||||
// Change level value to the opposite of the current level
|
||||
level = !digitalRead(ACTUATOR_ONOFF_GPIO);
|
||||
}
|
||||
# else
|
||||
level = !digitalRead(ACTUATOR_ONOFF_GPIO);
|
||||
# endif
|
||||
/*
|
||||
Handling of actuator control following the cases below:
|
||||
-Button press, if the button goes to ACTUATOR_BUTTON_TRIGGER_LEVEL we change the Actuator level
|
||||
-Status less switch state change (a switch without ON OFF labels), an action of this type of switch will trigger a change of the actuator state independently from the switch position
|
||||
*/
|
||||
void ActuatorTrigger() {
|
||||
uint8_t level = !digitalRead(ACTUATOR_ONOFF_GPIO);
|
||||
Log.trace(F("Actuator triggered %d" CR), level);
|
||||
digitalWrite(ACTUATOR_ONOFF_GPIO, level);
|
||||
// Send the state of the switch to the broker so as to update the status
|
||||
|
||||
Reference in new issue