User config division (#97)

* some minor correction after coadcy checks

* Put serial communication speed as a parameter in user_config.h

* complete gateway file

receiving ok
sending ko
#32

* add rfm69 to CI

* change receiver key and minor improvments

#32

now ok on receiving and sending with RFM69

* add schema and tested pinout for RFM69/RF/IR wiring

#32

* RFM69 library add

* Implement newremoteswitchlibrary for KlikAanKlikUit / ClickOnClickOff protocol

#3

* add dependency for CI and link to the library

* compilation error for arduino correction

* Sketch size decrease

* remove nano from CI

* Divide user_config into one file per gateway/sensor for lisibility
This commit is contained in:
Florian authored and GitHub committed 2017-09-01 00:41:29 +02:00
1 parent f8ede4aa94
commit 441ab1c0b7
11 files changed
+458 -253

No files matched your search

-15
View File
@@ -43,21 +43,6 @@
#include <stdint.h>
#include "SparkFunBME280.h"
#define bme280_always true // if false when the current value for light Level (Lux) is the same as previous one don't send it by MQTT
#define TimeBetweenReadingbme280 30000
/*----------------------------USER PARAMETERS-----------------------------*/
/*-------------DEFINE YOUR MQTT PARAMETERS BELOW----------------*/
#define TEMPBMEC "home/CLIMAtoMQTT/bme/tempc"
#define TEMPBMEF "home/CLIMAtoMQTT/bme/tempf"
#define HUMBME "home/CLIMAtoMQTT/bme/hum"
#define PRESSBME "home/CLIMAtoMQTT/bme/pa"
#define ALTIBMEM "home/CLIMAtoMQTT/bme/altim"
#define ALTIBMEFT "home/CLIMAtoMQTT/bme/altift"
//Time used to wait for an interval before resending measured values
unsigned long timebme280 = 0;
//Global sensor object
BME280 mySensor;