[SYS] Reduce Logs flash footprint (#2232)
By building only the log level required into LOG_LEVEL Co-authored-by: Florian <1technophile@users.noreply.github.com>
This commit is contained in:
1 parent
6e6b54b05e
commit
32174e37a5
52 files changed
+1187
-1136
No files matched your search
+13
-13
@@ -58,7 +58,7 @@ void setupZsensorBME280() {
|
||||
|
||||
mySensor.settings.commInterface = I2C_MODE;
|
||||
mySensor.settings.I2CAddress = BME280_i2c_addr;
|
||||
Log.notice(F("Setup BME280/BMP280 on address: %X" CR), BME280_i2c_addr);
|
||||
THEENGS_LOG_NOTICE(F("Setup BME280/BMP280 on address: %X" CR), BME280_i2c_addr);
|
||||
//***Operation settings*****************************//
|
||||
|
||||
// runMode Setting - Values:
|
||||
@@ -117,11 +117,11 @@ void setupZsensorBME280() {
|
||||
|
||||
int ret = mySensor.begin();
|
||||
if (ret == 0x60) {
|
||||
Log.notice(F("Bosch BME280 successfully initialized: %X" CR), ret);
|
||||
THEENGS_LOG_NOTICE(F("Bosch BME280 successfully initialized: %X" CR), ret);
|
||||
} else if (ret == 0x58) {
|
||||
Log.notice(F("Bosch BMP280 successfully initialized: %X" CR), ret);
|
||||
THEENGS_LOG_NOTICE(F("Bosch BMP280 successfully initialized: %X" CR), ret);
|
||||
} else {
|
||||
Log.notice(F("Bosch BME280/BMP280 failed: %X" CR), ret);
|
||||
THEENGS_LOG_NOTICE(F("Bosch BME280/BMP280 failed: %X" CR), ret);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -144,52 +144,52 @@ void MeasureTempHumAndPressure() {
|
||||
|
||||
// Check if reads failed and exit early (to try again).
|
||||
if (isnan(BmeTempC) || isnan(BmeTempF) || isnan(BmeHum) || isnan(BmePa) || isnan(BmeAltiM) || isnan(BmeAltiFt)) {
|
||||
Log.error(F("Failed to read from BME280/BMP280!" CR));
|
||||
THEENGS_LOG_ERROR(F("Failed to read from BME280/BMP280!" CR));
|
||||
} else {
|
||||
Log.trace(F("Creating BME280/BMP280 buffer" CR));
|
||||
THEENGS_LOG_TRACE(F("Creating BME280/BMP280 buffer" CR));
|
||||
StaticJsonDocument<JSON_MSG_BUFFER> BME280dataBuffer;
|
||||
JsonObject BME280data = BME280dataBuffer.to<JsonObject>();
|
||||
// Generate Temperature in degrees C
|
||||
if (BmeTempC != persisted_bme_tempc || bme280_always) {
|
||||
BME280data["tempc"] = (float)BmeTempC;
|
||||
} else {
|
||||
Log.trace(F("Same Degrees C don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Degrees C don't send it" CR));
|
||||
}
|
||||
|
||||
// Generate Temperature in degrees F
|
||||
if (BmeTempF != persisted_bme_tempf || bme280_always) {
|
||||
BME280data["tempf"] = (float)BmeTempF;
|
||||
} else {
|
||||
Log.trace(F("Same Degrees F don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Degrees F don't send it" CR));
|
||||
}
|
||||
|
||||
// Generate Humidity in percent
|
||||
if (BmeHum != persisted_bme_hum || bme280_always) {
|
||||
BME280data["hum"] = (float)BmeHum;
|
||||
} else {
|
||||
Log.trace(F("Same Humidity don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Humidity don't send it" CR));
|
||||
}
|
||||
|
||||
// Generate Pressure in Pa
|
||||
if (BmePa != persisted_bme_pa || bme280_always) {
|
||||
BME280data["pa"] = (float)BmePa;
|
||||
} else {
|
||||
Log.trace(F("Same Pressure don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Pressure don't send it" CR));
|
||||
}
|
||||
|
||||
// Generate Altitude in Meter
|
||||
if (BmeAltiM != persisted_bme_altim || bme280_always) {
|
||||
Log.trace(F("Sending Altitude Meter to MQTT" CR));
|
||||
THEENGS_LOG_TRACE(F("Sending Altitude Meter to MQTT" CR));
|
||||
BME280data["altim"] = (float)BmeAltiM;
|
||||
} else {
|
||||
Log.trace(F("Same Altitude Meter don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Altitude Meter don't send it" CR));
|
||||
}
|
||||
|
||||
// Generate Altitude in Feet
|
||||
if (BmeAltiFt != persisted_bme_altift || bme280_always) {
|
||||
BME280data["altift"] = (float)BmeAltiFt;
|
||||
} else {
|
||||
Log.trace(F("Same Altitude Feet don't send it" CR));
|
||||
THEENGS_LOG_TRACE(F("Same Altitude Feet don't send it" CR));
|
||||
}
|
||||
BME280data["origin"] = BMETOPIC;
|
||||
enqueueJsonObject(BME280data);
|
||||
|
||||
Reference in new issue
Block a user