[ONOFF] ESP32 Attempt to recover previous actuator state when power has been lost and overcurrent detection change (#1494)
And set the trigger of overCurrent to 2 consecutive measures
This commit is contained in:
1 parent
fa636bae0f
commit
1cdf6558a9
5 files changed
+164
-39
No files matched your search
@@ -39,7 +39,13 @@ Goes ON for 25 ms, then back to OFF:
|
||||
Goes OFF for 25 ms, then back to ON:
|
||||
`mosquitto_pub -t home/OpenMQTTGateway_MEGA/commands/MQTTtoONOFF -m '{"gpio":15,"cmd":"low_pulse","pulse_length":25}'`
|
||||
|
||||
Be aware that outputs are OFF by default when the board first start.
|
||||
Behavior at start in case of power loss (ESP32 only):
|
||||
The module will record per default the last state of the actuator and attempt to recover it upon restart.
|
||||
Example: if your relay is ON and a power outage occurs, when the power comes back the firmware will attempt to switch ON the relay again.
|
||||
|
||||
If you don't want this behavior you can set the macro `USE_LAST_STATE_ON_RESTART` to `false` at build time or use the command below at runtime:
|
||||
`mosquitto_pub -t home/OpenMQTTGateway_MEGA/commands/MQTTtoONOFF/config -m '{"uselaststate":false,"save":true}"'`
|
||||
The key `save` will persist the configuration upon restarts.
|
||||
|
||||
## FASTLED
|
||||
### The FASTLED module support 2 different operation modes
|
||||
|
||||
Reference in new issue
Block a user